StackLoom

StackLoom Monitor: live readings on any Windows PC.

Connect analyzers, flow meters and PLCs over Modbus and watch up to 50 parameters live, with limits, history and charts. No server, no cloud account, no browser address: it opens in its own window.

StackLoom Monitor showing six channels - SO2, NOx, SPM, CO, flue gas flow and temperature - all normal, each with a limit bar and a small trend line
The monitor screen with demonstration values.

Every reading, kept

Values are saved every minute and summarised every hour, so you can look back at any channel from the last hour to the last month and print it.

Trends screen with a 24-hour SO2 chart and the latest, average, lowest and highest values
Trends: 1 hour to 30 days, with latest, average, lowest and highest values and gaps marked.

What it connects to

Any instrument that speaks Modbus: gas analyzers, dust monitors, flow meters, temperature transmitters and PLCs.

ChannelsUp to 50, each with name, unit, range, scaling, offset, warning and alarm limits.
ConnectionsModbus RTU over RS-485 (COM port) and Modbus TCP over Ethernet.
Data types16- and 32-bit integers, 32-bit float, 64-bit double, with selectable byte order.
RegistersInput and holding registers. The program only reads; it never writes to an instrument.
ExportCSV that opens straight in Excel, and print or save any trend as PDF.
Runs onWindows 10 and 11 (64-bit). Listens on the PC itself only, so nothing is reachable from the network.

Live data

The plant view: from the stack, through the heat traced sample line, to the analyzer panel. The values here are demonstration data and move every two seconds; a real plant's data stays on the PC in the plant.

Stack signal flow
From the stack to the analyzer, live · Modbus RTU 9600 8N1
All channels normal
STACK
ANALYZER CABIN
Room
32.2 °C
Humidity
46.3 %RH
Stage 1
Sampling probe
Heat trace line
156.6 °C
ANALYZER PANEL
Device 1 · SO2 / NOx
mg/Nm³
SO2
201.5
NOx
189.3
Device 2 · SPM
mg/Nm³
29.9
Sample handling
Heat trace control
Sample pump
Filter
Backblow valve
Standard gas valve
Air compressor
Demonstration data and lamp status. Values update every two seconds in this design.

Swipe sideways to see the analyzer panel.

Support

Stuck on a channel or a connection? Send us the setup, not a password. Nothing on the instrument is changed without your confirmation.

  1. Note the problemWhich channel, what you see, and the message on the screen.
  2. Copy the setupOpen the channel and press "Copy setup". It holds the connection, register, range and note in plain text.
  3. Send it to usPaste it in an e-mail with a screenshot. Call for anything urgent.
  4. Get a replyWe check the setup and tell you the fix, or arrange a remote session with your permission.

Common checks

No responseCable, COM port, slave ID, baud rate and parity. The "Test read" button shows the reply.
Odd valuesData type and byte order. Change the byte order only if the test read gives nonsense.
Wrong scaleMultiplier and offset, applied in that order.
LicenceCopy the Machine ID from the licence window and send it with your site name.

Contact

Phone: +91 99246 92690
E-mail: mahesh.shrimali@outlook.com

Vadodara, Gujarat. Please send the copied setup and a screenshot with every request.